| Specifications |
| DMZ-2
Model |
40
U |
80
U |
120
U |
170
U |
240
U |
| Available
Hoppers (lbs) |
33
or 55 |
110 |
165,220,330 |
330
or 440 |
550
or 660 |
| Hopper Volume (ft3) |
0.88 |
3.0 |
4.4, 6.0 or 8.8 |
4.4 or 12.0 |
14.8 or 17.6 |
| Drying
Hopper Insulation |
Glass
wool and outer jacket |
| Dew
Point (°F) |
-40
(86°F, 76%RH) |
| Airflow
(CFM) |
23 |
47 |
70 |
106 |
165 |
| Drying
Blower (KW) |
.50 |
.85 |
1.55 |
1.75 |
2.55 |
| Regeneration
Blower (KW) |
.057 |
.113 |
.113 |
.420 |
1.15 |
| Drying
Heater (KW) |
1.5 (2.1H) |
2.4 (4.0H0 |
3.3 (6.0H) |
4.0 (7.8H) |
6.0 (12.4H) |
| Regeneration
Heater (KW) |
1.5 |
2.4 |
3.1 |
5.8 |
7.7 |
| Absorbent
|
Zeoliterotor |
| Absorbent Motor (KW) |
.015 |
| After
cooler Flow (GPM) |
1.5 |
3.7 |
4.0 |
4.0 |
5.2 |
| Control |
Microprocessor w/PID Heating |
| Auto Start Timer |
Range: 10 min to 99 hrs 50min |
| Power Supply (Volts) |
AC
230 or 460 Volt, 3-Phase, 60Hz |
| Maxium Temperature |
266°F (H-356° F) |
| Breaker-Amps (230/460V) |
20/20 |
30/40 |
40/50 |
50/30 |
75/40 |
| Hi-Temp Model |
- |
- |
- |
60/40 |
100/50 |
| Weight
(Lbs) |
264 |
352 |
440 |
760 |
800 |
| System
Protection |
Overheat
Alarm, Reverse Phase Alarm, Overload Alarm,
Automatic Cool Down Mode |
| System
Features: |
Reduced
Drying Time by 50%, Energy Saving Design,
15-Year Desiccant, Sheathed-Type Heaters |
| Available
Options: |
Weekly Timer, Dew Point Meter, Filter Alarm, Floor Frame, V-Box, Insulated Hopper |
|
|
|
|
| |
|
|